FortiGate-5050 shelf alarm panel FortiGate-5050 chassis
FortiGate-5050-R Chassis Guide
10 01-30000-87717-20090108
http://docs.fortinet.com/ • Feedback
Figure 4: FortiGate-5050 shelf alarm panel front panel
Figure 5 shows the connections between the primary and secondary shelf managers and
the shelf alarm panel.
Table 3: FortiGate-5050 shelf alarm panel LEDs
LED State Description
CRT
(critical)
Off Normal operation.
Red Indicates a critical alarm.
Blinking
Red
Alarm cutoff (ACO) activated by pressing the alarm LED reset button.
MAJ (major) Off Normal operation.
Red Indicates a major alarm.
Blinking
Red
Alarm cutoff (ACO) activated by pressing the alarm LED reset button.
MIN (minor) Off Normal operation.
Amber Indicates a minor alarm.
Blinking
Amber
Alarm cutoff (ACO) activated by pressing the alarm LED reset button.
USER3
USER2
USER1
Off Normal operation
Amber Indicates a user-definable alarm.
Blinking
Amber
Alarm cutoff (ACO) activated by pressing the alarm LED reset button.
Table 4: FortiGate-5050 shelf alarm panel connectors
Connector Type Speed Protocol Description
SERIAL 1 RJ-45 9600 bps,
8/N/1
RS-232
serial
Serial connection to the primary shelf manager
command line interface.
SERIAL 2 RJ-45 9600 bps,
8/N/1
RS-232
serial
Serial connection to the secondary shelf
manager command line interface.
ALARM micro
DB-15
male
N/A Telco
Form-c
The external dry relay Telco alarm interface
(48VDC) provides Telco form-c relay
connections for minor, major and critical power
faults. The cable required to connect to the
alarm interface is not supplied by Fortinet.
5050SAP
SERIAL
1
SERIAL
2
ALARM
Retention
Screw
Retention
Screw
Telco Alarm
Interface
Alarm
LED Reset
Button
Minor Alarm (MIN) (Amber)
Major Alarm (MAJ) (Red)
Critical Alarm (CRT) (Red)
User 3 Alarm (Amber)
User 2 Alarm (Amber)
User 1 Alarm (Amber)
SERIAL 1 (Primary
Shelf Manager)
SERIAL 2 (Secondary
Shelf Manager)